Skip to main content

B136F200A : The specified PCIE device bus fatal error asserted.

The specified PCIE device bus fatal error asserted.

Bus Fatal Error

Severity

Error

User Action

Complete the following steps:

  1. If the server and/or any attached cables were recently installed, moved, serviced or upgraded, check whether the processor, the adapter and any attached cables is properly seated and check visually whether there is any foreign material in processor socket and any PCIe slot. If yes, reseat the processor, the adapter and any attached cables or clean the foreign material in processor socket and that PCIe slot.
  2. Reload device driver.
  3. Check the Lenovo support site for an applicable device driver, firmware update, or other information that applies to this error. Load the new device driver and install any required firmware updates.
  4. Swap other PCIe devices in the slot, if the problem recurs on the same PCIe slot, inspect the PCIe slot for any damage. If the problem is solved, change another identical PCIe card to check whether the problem can be solved again.
  5. If the problem persists, collect service data log from the BMC Web interface and contact Lenovo Support (https://datacentersupport.lenovo.com/serviceprovider).