1 x AnyBay + 3 x SAS/SATA backplanes
Use this section to understand the signal cable routing for one AnyBay backplane and three SAS/SATA backplanes.
Note
- Ensure that you observe the installation rules and sequence order in PCIe riser and adapter installation rules and order and Drive backplane installation rules and order.
- For more information on the power cable routing, see 2.5-inch drive backplane power cable routing.
- Depending on your configuration, the RAID/HBA adapter will be installed in different riser locations.
- Connections between connectors; 1↔1, 2↔2, 3↔3, ... n↔n
- When routing the cables, ensure that all cables are routed appropriately through the cable guides.
This configuration contains the following storage controller combinations:
16i + 16i RAID/HBA adapter
NVMe cable routing | ||
---|---|---|
From | To | Cable |
1 BP1: NVMe 0-1 | System board: NVMe 10 | MCIO x8 to MCIO x8 (440 mm) |
2 BP1: NVMe 2-3 | System board: NVMe 9 | MCIO x8 to MCIO x8 (440 mm) |
3 BP1: NVMe 4-5 | System board: NVMe 1 | MCIO x8 to Swift x8 (190 mm) |
4 BP1: NVMe 6-7 | System board: NVMe 2 | MCIO x8 to Swift x8 (190 mm) |
SAS/SATA cable routing to riser 3 | SAS/SATA cable routing to riser 2 | SAS/SATA cable routing to riser 1 |
---|---|---|
Note Depending on your configuration, the RAID/HBA adapter will be installed in different riser locations. | ||
From | To | Cable |
1 BP1: SAS/SATA |
|
|
2 BP2: SAS/SATA |
|
|
3 BP3: SAS/SATA |
|
|
4 BP4: SAS/SATA |
|
|
8i + 32i RAID/HBA adapter
NVMe cable routing | ||
---|---|---|
From | To | Cable |
1 BP1: NVMe 0-1 | System board: NVMe 10 | MCIO x8 to MCIO x8 (440 mm) |
2 BP1: NVMe 2-3 | System board: NVMe 9 | MCIO x8 to MCIO x8 (440 mm) |
3 BP1: NVMe 4-5 | System board: NVMe 1 | MCIO x8 to Swift x8 (190 mm) |
4 BP1: NVMe 6-7 | System board: NVMe 2 | MCIO x8 to Swift x8 (190 mm) |
SAS/SATA cable routing to riser 3 | SAS/SATA cable routing to riser 2 | SAS/SATA cable routing to riser 1 |
---|---|---|
Note Depending on your configuration, the RAID/HBA adapter will be installed in different riser locations. | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i Gen 4: C0 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
2 BP2: SAS/SATA | 32i Gen 4: C1 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
3 BP3: SAS/SATA | 32i Gen 4: C2 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
4 BP4: SAS/SATA |
|
|
16i + 32i RAID/HBA adapter
NVMe cable routing | ||
---|---|---|
From | To | Cable |
1 BP1: NVMe 0-1 | System board: NVMe 10 | MCIO x8 to MCIO x8 (440 mm) |
2 BP1: NVMe 2-3 | System board: NVMe 9 | MCIO x8 to MCIO x8 (440 mm) |
3 BP1: NVMe 4-5 | System board: NVMe 1 | MCIO x8 to Swift x8 (190 mm) |
4 BP1: NVMe 6-7 | System board: NVMe 2 | MCIO x8 to Swift x8 (190 mm) |
SAS/SATA cable routing to riser 3 | SAS/SATA cable routing to riser 2 | SAS/SATA cable routing to riser 1 |
---|---|---|
Note Depending on your configuration, the RAID/HBA adapter will be installed in different riser locations. | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i Gen 4: C0 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
2 BP2: SAS/SATA | 32i Gen 4: C1 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
3 BP3: SAS/SATA | 32i Gen 4: C2 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
4 BP4: SAS/SATA |
|
|
32i + 32i RAID adapter
NVMe cable routing | ||
---|---|---|
From | To | Cable |
1 BP1: NVMe 0-1 | System board: NVMe 10 | MCIO x8 to MCIO x8 (440 mm) |
2 BP1: NVMe 2-3 | System board: NVMe 9 | MCIO x8 to MCIO x8 (440 mm) |
3 BP1: NVMe 4-5 | System board: NVMe 1 | MCIO x8 to Swift x8 (190 mm) |
4 BP1: NVMe 6-7 | System board: NVMe 2 | MCIO x8 to Swift x8 (190 mm) |
SAS/SATA cable routing to riser 3 | SAS/SATA cable routing to riser 1 | |
---|---|---|
Note Depending on your configuration, the RAID/HBA adapter will be installed in different riser locations. | ||
From | To | Cable |
1 BP1: SAS/SATA | 32i Gen 4: C0 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
2 BP2: SAS/SATA | 32i Gen 4: C1 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
3 BP3: SAS/SATA | 32i Gen 4: C2 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
4 BP4: SAS/SATA | 32i Gen 4: C0 | Gen 4: SlimSAS x8 to SlimSAS x8 (1000 mm) |
Give documentation feedback