Adapter replacement
Adapters are in several locations in the I/O tray that is accessed from the rear of the server. You can install up to 17 adapters in the server. The removal and installation procedures for each riser type are different and are described in the following topics:
PCIe adapters 1 to 4: see Remove a PCIe adapter from slot 1 to 4 and Install a PCIe adapter in slot 1 to 4
PCIe adapters 5 to 8 and the LOM adapter (slot 9):
For PCIe adapters 5 to 8, see Remove a PCIe adapter from slot 5 to 8 and Install a PCIe adapter in slot 5 to 8
For the LOM adapter (slot 9), see Remove a LOM adapter from slot 9 and Install a LOM adapter in slot 9
PCIe adapters 10 to 15: see Remove a PCIe adapter from slot 10 to 15 and Install a PCIe adapter in slot 10 to 15
I/O adapters 16 to 17: see Remove an I/O adapter from slot 16 to 17 and Install an I/O adapter in slot 16 to 17
Installation considerations for the Mellanox Innova™-2 Flex Open Programmable SmartNIC
If you install the Mellanox Innova™-2 Flex Open Programmable SmartNIC in the ThinkSystem SR950, the maximum supported ambient temperature for the system is 35°C.
The Mellanox Innova™-2 Flex Open Programmable SmartNIC is not supported in the following adapter slots: 1, 5, and 10.
When installing the Mellanox Innova™-2 Flex Open Programmable SmartNIC in a 4-socket configuration:
A maximum of two of these adapters can be installed in the system.
The Mellanox Innova™-2 Flex Open Programmable SmartNIC can be installed only in adapter slots 6, 7, or 17.
The installation of two of these adapters in contiguous, sequential slots is not supported. For example, you cannot install two adapters in slots 6 and 7.
When installing the Mellanox Innova™-2 Flex Open Programmable SmartNIC in an 8-socket configuration:
A maximum of four of these adapters can be installed in the system.
The Mellanox Innova™-2 Flex Open Programmable SmartNIC can be installed only in adapter slots 2, 3, 4, 6, 7, 11, 12, 13, 14, 15, 16, or 17.
The installation of two of these adapters in contiguous, sequential slots is not supported. For example, you cannot install two adapters in slots 2 and 3.