Install the power distribution board

Follow instructions in this section to install the power distribution board of the hot-swap redundant power supply.

About this task

To avoid potential danger, read and follow the following safety statements.
  • S001
    shock hazard
    DANGER
    danger
    Electrical current from power, telephone, and communication cables is hazardous.

    To avoid a shock hazard:

    • Connect all power cords to a properly wired and grounded electrical outlet/source.
    • Connect any equipment that will be attached to this product to properly wired outlets/sources.
    • When possible, use one hand only to connect or disconnect signal cables.
    • Never turn on any equipment when there is evidence of fire, water, or structural damage.
    • The device might have more than one power cord, to remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
  • S002
    disconnect all power
    CAUTION
    The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safety.

  • Touch the static-protective package that contains the component to any unpainted metal surface on the server; then, remove it from the package and place it on a static-protective surface.

Procedure

  1. Lay the server on its side for easier operation.
  2. Hold the power distribution board by its edges, and align the slots on the board with the four tabs on the power supply cage; then, slide the power distribution board toward the power supply cage until it clicks into place..
    Figure 1. Installing the power distribution board of the hot-swap power supply
    Installing the power distribution board of the hot-swap power supply
  3. Connect the power cables to the power distribution board; then, properly route the cables, and secure the cables with the cable clips.
  4. Align the slot on the power distribution board cover with the one on the power supply cage; then, secure the power distribution board cover with the screw.
    Figure 2. Installing the power distribution board cover
    Installing the power distribution board cover

After you finish

Demo video