80010701-1002ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted. (PCI Riser 2 Temp)
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted. (PCI Riser 2 Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor going high has asserted.
May also be shown as 800107011002ffff or 0x800107011002ffff
Severity
Warning
Alert Category
Warning - Temperature
Serviceable
Yes
SNMP Trap ID
12
Automatically Notify Support
No
User Response
- Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node cover is installed and completely closed.
- Make sure the fans are operating, and there are no obstructions to the airflow.
- Reduce the Ambient temperature. The system must be operating within the specifications.(see Features and specifications for more information)