806f010d-041cffff : The Drive [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 28)
The Drive [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 28)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d041cffff or 0x806f010d041cffff
Severity
Error
Alert Category
Critical - Hard Disk drive
Serviceable
Yes
SNMP Trap ID
5
Automatically Notify Support
Yes
User Response
- Run the hard disk drive diagnostic test on drive n.
- Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
- Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
Give documentation feedback