Skip to main content

806f0a0c-2014ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

May also be shown as 806f0a0c2014ffff or 0x806f0a0c2014ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0146

SNMP Trap ID

0

Automatically Notify Support

No

User Response

  1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node cover is installed and completely closed.
  2. Make sure the fans are operating, and there are no obstructions to the airflow.
  3. Reduce the Ambient temperature. The system must be operating within the specifications (see Features and specifications for more information).