806f0107-0302ffff : An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 2)

An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 2)

This message is for the use case when an implementation has detected an Over-Temperature Condition Detected for Processor.

May also be shown as 806f01070302ffff or 0x806f01070302ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0036

SNMP Trap ID

0

Automatically Notify Support

No

User Response

  1. Make sure the air baffles/heat sink are placed and correctly installed; and make sure the node cover is installed and completely closed.
  2. Make sure the fans are operating, and there are no obstructions to the airflow.
  3. Reduce the Ambient temperature. The system must be operating within the specifications.(see Features and specifications for more information)
  4. Make sure that the heat sink for microprocessor n is installed correctly.
  5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)