80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

A voltage has dropped below its specified threshold.

May also be shown as 800102020701ffff or 0x800102020701ffff

Severity

Error

Alert Category

Critical - Voltage

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0480

SNMP Trap ID

1

Automatically Notify Support

Yes

User Response

Use one of the following procedures:

  • If the specified sensor is SysBrd 3.3V or SysBrd 5V, replace the system board.
  • If the specified sensor is SysBrd 12V, check the Chassis Management Module or Flex System Manager event log for power-supply-related issues, and resolve those issues. If the problem remains, replace the system board.