80070617-2c02ffff : Sensor Mezz Exp 2 Fault has transitioned to non-recoverable.
Sensor Mezz Exp 2 Fault has transitioned to non-recoverable.
A problem was detected in the I/O expansion adapter in I/O expansion connector 2. The adapter is unable to initialize.
May also be shown as 800706172c02ffff or 0x800706172c02ffff
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Response
Complete the following steps:
- Remove the I/O expansion adapter in I/O expansion connector 2.
- Try to power on the chassis.
- If the chassis successfully powers on, complete the following steps:
- Check the ServerProven website to make sure that recently installed components are compatible with the chassis.
- Inspect the previously installed components for physical damage.
- If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the I/O expansion adapter.
- If the chassis successfully powers on, complete the following steps: