806f0107-2584ffff : An over-temperature condition has been detected on [ProcessorElementName].
An over-temperature condition has been detected on [ProcessorElementName].
The temperature of the specified microprocessor has risen above its specified threshold.
May also be shown as 806f01072584ffff or 0x806f01072584ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Make sure that the heat sink for the specified microprocessor is securely installed.
- Make sure that the heat sink for the specified microprocessor is installed correctly and the thermal material is correctly applied.
- Replace the specified microprocessor.
Give documentation feedback