Skip to main content

0E200007 : Power denied to node [arg1] because it has unidentified hardware.

Power denied to node [arg1] because it has unidentified hardware.

The specified node contains components that the Chassis Management Module cannot identify. For example, the node might contain an expansion card that is not recognized. Therefore, the power requirements of the component cannot be determined.

Severity

Warning

Alert Category

Nodes (Warning)

Log Source

Node_07

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0170

SNMP Trap ID

mmTrapBladeN

Automatically Notify Support

No

User Response

Complete the following steps until the problem is solved:

  1. Check the Chassis Management Module event log for other problems pertaining to the node, such as invalid vital product data (VPD), and solve them.
  2. If new hardware has been added to the node, check the firmware change history for applicable updates and, if necessary, update the node firmware.
  3. Try running the node without optional components such as expansion cards.