35010C0A : System-management processor firmware on [arg1] does not support Authentication Only mode.
System-management processor firmware on [arg1] does not support Authentication Only mode.
Authentication Only mode enabled on the Chassis Management Module is not supported by the system-management processor for the specified node. Users might not be able to log into the node system-management processor.
Severity
Warning
Alert Category
Nodes (Warning)
Log Source
Node_10
Serviceable
Yes
Recoverable
Yes
Chassis LED that is Lit
None
SNMP Trap ID
mmTrapBladeN
Automatically Notify Support
No
User Response
Ensure that the node system-management processor has the correct level of firmware to support the security functions enabled on the Chassis Management Module. If you cannot log onto the node system-management processor, you might need to temporarily disable Authentication Only mode on the CMM.
Give feedback