Skip to main content

0201020B : SMM2 Brd 3.3V: Voltage sensor, critical event was asserted, reading value %V (Threshold %V)

SMM2 Brd 3.3V: Voltage sensor, critical event was asserted, reading value %V (Threshold %V)

Asserted when voltage sensed on 3.3V power rail is lower than lower critical threshold.

Severity

Error

Alert Category

System - SMM2 system event

SNMP Trap ID

33620491

User Action

  1. Virtual reset SMM2 via Web GUI or IPMI command.
  2. If the event persists, ensure all populated compute nodes are completely power off, then reseat SMM2 module. (Service technician only)
  3. If the event persists, ensure all populated compute nodes are completely power off, then replace the SMM2 module. (Service technician only)
  4. If the event persists, please consult with technical service.