0201020E : SMM2 Brd VBAT: Voltage sensor, critical event was asserted, reading value %V (Threshold %V)
SMM2 Brd VBAT: Voltage sensor, critical event was asserted, reading value %V (Threshold %V)
Asserted when voltage sensed on coin battery output voltage is lower than lower critical threshold.
Severity
Error
Alert Category
System - SMM2 system event
SNMP Trap ID
33620494
User Action
- Virtual reset SMM2 via Web GUI or IPMI command.
- If the event persists, ensure all populated compute nodes are completely power off, then reseat SMM2 module. (Service technician only)
- If the event persists, ensure all populated compute nodes are completely power off, then replace the coin battery on the SMM2 module. (Service technician only)
- If the event persists, ensure all populated compute nodes are completely power off, then replace the SMM2 module. (Service technician only)
- If the event persists, please consult with technical service.
Give documentation feedback