Skip to main content

21070142 : Node 3 Pwr Perm: Slot Or Connector, transition to Non-Critical from OK was asserted.

Node 3 Pwr Perm: Slot Or Connector, transition to Non-Critical from OK was asserted.

The indicated compute node hasn't acquired power permission to into ready state.

Severity

Warning

Alert Category

Node - Node event

SNMP Trap ID

554107202

User Action

  1. Please check the enclosure event refer to following section
    • For DW612 enclosure
      • If the Shared IO mode is enabled, the auxiliary node will acquire power permisson once the primary node is power on.
    • For DA240 enclosure
      • Ensure all fan modules are well installed and have no fault event.
  2. If the event persists, reseat the indicated compute node if the node is under power fault condition. (Service technician only)
  3. If the event persists, reset the BMC on indicated compute node.
  4. If the event persists, ensure the indicated compute node is completely power off and then reseat it. (Service technician only)
  5. If the event persists, replace the indicated compute node. (Service technician only)
  6. If the event persists, please consult with technical service.