180702F8 : Encl Cap Fail: Chassis, transition to Critical from less severe was asserted.
Encl Cap Fail: Chassis, transition to Critical from less severe was asserted.
Unable to apply enclosure power capping.
Severity
Error
Alert Category
System - SMM2 system event
SNMP Trap ID
403112696
User Action
- Re-configure the enclosure power capping setting from web GUI or IPMI command.
- If the event persists, check the power capping setting and status of populated compute nodess to identify fault compute node(s), reset the BMC on indicated compute node(s).
- If the event persists, ensure the indicated compute node is completely power off, and then reseat it. (Service technician only)
- If the event persists, replace the indicated compute node. (Service technician only)
- If the event persists, please consult with technical service.