Skip to main content

180702F8 : Encl Cap Fail: Chassis, transition to Critical from less severe was asserted.

Encl Cap Fail: Chassis, transition to Critical from less severe was asserted.

Unable to apply enclosure power capping.

Severity

Error

Alert Category

System - SMM2 system event

SNMP Trap ID

403112696

User Action

  1. Re-configure the enclosure power capping setting from web GUI or IPMI command.
  2. If the event persists, check the power capping setting and status of populated compute nodess to identify fault compute node(s), reset the BMC on indicated compute node(s).
  3. If the event persists, ensure the indicated compute node is completely power off, and then reseat it. (Service technician only)
  4. If the event persists, replace the indicated compute node. (Service technician only)
  5. If the event persists, please consult with technical service.