02010708 : SMM2 Brd 1.15V: Voltage sensor, warning event was asserted, reading value %V (Threshold %V)
SMM2 Brd 1.15V: Voltage sensor, warning event was asserted, reading value %V (Threshold %V)
Asserted when voltage sensed on 1.15V power rail is higher than high non-critical threshold.
Severity
Information
Alert Category
System - SMM2 system event
SNMP Trap ID
33621768
User Action
- Virtual reset SMM2 via Web GUI or IPMI command.
- If the event persists, ensure all populated compute nodes are completely power off, then reseat SMM2 module. (Service technician only)
- If the event persists, ensure all populated compute nodes are completely power off, then replace the SMM2 module. (Service technician only)
- If the event persists, please consult with technical service.