Skip to main content

0201070A : SMM2 Brd 2.5V: Voltage sensor, warning event was asserted, reading value %V (Threshold %V)

SMM2 Brd 2.5V: Voltage sensor, warning event was asserted, reading value %V (Threshold %V)

Asserted when voltage sensed on 2.5V power rail is higher than upper non-critical threshold.

Severity

Information

Alert Category

System - SMM2 system event

SNMP Trap ID

33621770

User Action

  1. Virtual reset SMM2 via Web GUI or IPMI command.
  2. If the event persists, ensure all populated compute nodes are completely power off, then reseat SMM2 module. (Service technician only)
  3. If the event persists, ensure all populated compute nodes are completely power off, then replace the SMM2 module. (Service technician only)
  4. If the event persists, please consult with technical service.