10 x 2.5'' SAS/SATA (one processor)
See this section to understand the cable routing of 10 front SAS/SATA drives with the 10 x 2.5 AnyBay backplane (Gen 4) installed.
To connect cables for a 7mm drive backplane, refer to 7mm drive backplane.
To connect power cables for a backplane for standard 2.5'' or 3.5'' drives, refer to Cable routing for backplane power.
To connect cables for M.2 drives, refer to M.2 drive backplane.
To connect cables for a CFF RAID adapter, refer to CFF RAID adapter
Cable routing for onboard configuration
The following illustrations and tables show the mapping relationship between backplane connectors and system board connectors for onboard configuration.
The following figure illustrates the cable routing for the configuration of 10 front SAS/SATA drives bays. Connections between connectors: 1 ↔ 1, 2 ↔ 2, 3 ↔ 3, ... n ↔ n.

Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1 SATA connector 2 |
2 SAS 2 | 2 SATA connector 4 |
Cable routing with an SFF HBA/RAID adapter
The following tables show the mapping relationship between backplane connectors and a 16i SFF HBA/RAID adapter (Gen 3 or Gen 4).

Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1
|
2 SAS 2 | 2
|

Backplane/adapter | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1 C0, C1 |
2 SAS 2 | 2 C2 | |
Rear BP (SAS) | 4 SAS | 3 C3 |

Backplane/adapter | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1 C0 |
2 SAS 2 | 2 C1 | |
Rear BP (SAS) | 2 SAS | 2 C1 |
Cable routing with a CFF RAID adapter

Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0 | 1 C0 |
2 SAS 1 | 2 C1 | |
3 SAS 2 | 3 C2 | |
CFF RAID adapter | 4 MB input | 4 PCIe connector 7 |

Backplane/adapter | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0 | 1 C0 |
2 SAS 1 | 2 C1 | |
3 SAS 2 | 3 C2 | |
Rear BP (SAS) | 4 SAS | 4 C3 |
CFF RAID adapter | 5 MB input | 5 PCIe connector 7 |

Backplane/adapter | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0 | 1 C0 |
2 SAS 1 | 2 C1 | |
3 SAS 2 | 3 C2 | |
Rear BP (SAS) | 4 SAS | 4 C3 |
CFF RAID adapter | 5 MB input | 5 PCIe connector 4 |