32i RAID adapter + retimer card
Front backplanes: 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch AnyBay
The following shows the cable connections for 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch AnyBay configuration with one 32i RAID adapter and one retimer card.
From | To |
---|---|
Backplane 1: SAS | 32i RAID adapter on PCIe slot 2: C0 |
Backplane 2: SAS | 32i RAID adapter on PCIe slot 2: C1 |
Backplane 3: SAS | 32i RAID adapter on PCIe slot 2: C2 |
Backplane 3: NVMe 0-1, 2-3 | Onboard: PCIe 1, PCIe 2 |
Backplane 3: NVMe 4-5, 6-7 | Retimer card on PCIe slot 1: C0, C1 |
Connections between connectors: 1 ↔ 1, 2 ↔ 2, 3 ↔ 3, ... n ↔ n
Figure 1. SAS/SATA cable routing | Figure 2. NVMe cable routing |
Rear backplane: 4 x 2.5-inch SAS/SATA
The following shows the cable connections for a rear 4 x 2.5-inch SAS/SATA backplane if installed.
From | To |
---|---|
Backplane 4: SAS | 32i RAID adapter on PCIe slot 2: C3 |
Backplane 4: PWR | Riser 1: PWR1, PWR2 |
Figure 3. Cable routing for the rear 4 x 2.5-inch SAS/SATA backplane
Give documentation feedback