Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.
Procedure
Install the riser assembly into chassis.
Riser 1 assembly (same for riser 2 assembly)
Note
The following uses the 3-slot riser cage as an example for illustration. The replacement procedure for the 1-slot riser cage is similar.
Figure 1. Riser 1 assembly installation
Align the riser card with the riser slot on the system board assembly. Carefully press the riser card straight into the slot until it is securely seated.
Tighten the screw to secure the riser cage.
Riser 3 assembly
Note
The following uses the Gen 5 riser 3 cage as an example for illustration. The replacement procedure is the same for Gen 4 riser 3 cage.
Figure 2. Riser 3 assembly installation
4LP Riser 3/4 assembly
Install the riser cage tray.
Figure 3. Riser cage tray installation
Align the riser cage tray with the pin and screw holes on the chassis.
Install the screws to fix the riser cage tray to the chassis.
Install riser 3 assembly and riser 4 assembly into the riser cage.