Skip to main content

Two processors

Use the section to understand the E3.S drive backplane cable routing for the server configuration with CX-7 mezz board and two processors.

Note
  • Make sure the backplane cables are placed underneath the cables that are connected to the CX-7 carrier board and the CX-7 mezz board.
  • Make sure the cables that go through the right side of the server are routed under the radiator bracket as illustrated.
  • Make sure the backplane power cable is routed above the radiator bracket as illustrated.
  • After connecting cables, equally divide the cables that go through the right side of the front drive tray into two bundles, and secure them with the two cable ties.
    Figure 1. Securing cables with cable ties
    Securing cables with cable ties
Figure 2. E3.S drive backplane cable routing
E3.S drive backplane cable routing
CableFromTo
1Backplane: EDSFF 0-1System board assembly: PCIe connector 2
2Backplane: Power connectorSystem board assembly: Backplane power connector
3Backplane: EDSFF 2-3System board assembly: PCIe connector 6