Remove the fixed power supply unit

Follow instructions in this section to remove the fixed power supply unit.

About this task

To avoid potential danger, read and follow the following safety statements.
  • S001
    shock hazard
    DANGER
    danger
    Electrical current from power, telephone, and communication cables is hazardous.

    To avoid a shock hazard:

    • Connect all power cords to a properly wired and grounded electrical outlet/source.
    • Connect any equipment that will be attached to this product to properly wired outlets/sources.
    • When possible, use one hand only to connect or disconnect signal cables.
    • Never turn on any equipment when there is evidence of fire, water, or structural damage.
    • The device might have more than one power cord, to remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
    Figure 1. Fixed power supply label on the cover
    Fixed power supply label on the cover

    The following tips describe the information that you must consider when you remove a power supply with dc input.

    NEVER CONNECT AND DISCONNECT THE POWER SUPPLY CABLE AND EQUIPMENT WHILE YOUR EQUIPMENT IS POWERED ON WITH DC SUPPLY (hot-plugging). Otherwise you may damage the equipment and result in data loss, the damages and losses result from incorrect operation of the equipment will not be covered by the manufacturers’ warranty.

  • S002
    disconnect all power
    CAUTION
    The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
  • S035
    shock hazard
    CAUTION

    Never remove the cover on a power supply or any part that has this label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.

Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safety.

  • Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.

  • If the server is in a rack, remove it from the rack.

  • Remove any locking device that secures the server cover, such as a Kensington lock or a padlock.

Procedure

  1. Remove the server cover. See Remove the server cover.
  2. Disconnect all cables on the fixed power supply from the system board.
  3. Remove a fixed power supply.
    1. Remove the four screws at the rear of the chassis that secure the power supply.
    2. Push the fixed power supply from the rear until it is released from the metal retaining tab, and carefully lift the power supply out of the chassis.
    Figure 2. Removing a fixed power supply
    Removing a fixed power supply

After you finish

If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Demo video

Watch the procedure on Youtube