Replacing a compute book

This information provides instructions on how to replace the compute book.

Note
The information and installation procedures in this documentation apply to both the 4-socket and the 8-socket configurations of the server, unless otherwise specified. Most of the illustrations in the documentation show the 4-socket configuration of the server.

The following are notes and information that you must consider when you install the compute book in the server:

  • The compute books should be installed from left to right (facing the front of the server).
  • A minimum of two compute books must be installed in the 4-socket (x3850 X6) server.
  • A minimum of four compute books must be installed in the 8-socket (x3950 X6) server.
  • Each compute book must have a minimum of one microprocessor and one DIMM installed.
  • The 4-socket (x3850 X6) server supports compute book configurations of two or four. These are the only configurations supported. The following tables list the installation sequence for the supported compute book configurations.
    Table 1. Installation sequence for the two compute books configuration for a 4-socket server.

    Table with four columns and headers with the install sequence information for the configuration of two compute books in a 4-socket server

    Compute bookbay 1bay 2bay 3bay 3
    1compute book 1   
    2 compute book 2  
    Table 2. Installation sequence for the four compute books configuration for a 4-socket server.

    Table with four columns and headers with the install sequence information for the configuration of four compute books in a 4-socket server

    Compute bookBay 1Bay 2Bay 3Bay 4
    1compute book 1   
    2 compute book 2  
    3  compute book 3 
    4   compute book 4
  • The 8-socket (x3950 X6) server supports compute book configurations of four, six, or eight. These are the only configurations supported. The following tables list the installation sequence for the supported compute book configurations.
    Table 3. Installation sequence for the four compute books configuration for an 8-socket server.

    Table with four columns and headers with the install sequence information for the configuration of four compute books in an 8-socket server

    Compute bookTop node (bay 1)Top node (bay 2)Top node (bay 3)Top node (bay 4)Bottom node (bay 1)Bottom node (bay 2)Bottom node (bay 3)Bottom node (bay 4)
    1compute book 1       
    2 compute book 2      
    3    compute book 3   
    4     compute book 4  
    Table 4. Installation sequence for the six compute books configuration for an 8-socket server.

    Table with four columns and headers with the install sequence information for the configuration of six compute books in an 8-socket server

    Compute bookTop node (bay 1)Top node (bay 2)Top node (bay 3)Top node (bay 4)Bottom node (bay 1)Bottom node (bay 2)Bottom node (bay 3)Bottom node (bay 4)
    1compute book 1       
    2 compute book 2      
    3    compute book 3   
    4     compute book 4  
    5      compute book 5 
    6       compute book 6
    Table 5. Installation sequence for the eight compute books configuration for an 8-socket server.

    Table with four columns and headers with the install sequence information for the configuration of eight compute books in an 8-socket server

    Compute bookTop node (bay 1)Top node (bay 2)Top node (bay 3)Bottom node (bay 4)Bottom node (bay 1)Bottom node (bay 2)Bottom node (bay 3)Bottom node (bay 4)
    1compute book 1       
    2 compute book 2      
    3  compute book 3     
    4   compute book 4    
    5    compute book 5   
    6     compute book 6  
    7      compute book 7 
    8       compute book 8
  • For more information about the compute book, see Compute book. For more information about installing DIMMs, see Installing a memory module.
  • For a list of supported devices, see the Lenovo ServerProven website.

To install the compute book, complete the following steps:

  1. Reinstall the microprocessor and heat sink on the new compute book (see Replacing a microprocessor and heat sink).
  2. Reinstall the DIMMs (see Replacing a memory module).
  3. Replace the compute book covers. Align the cover over the rear of the compute book and slide it forward (toward the front of the compute book) until it is seated in place.
  4. Reinstall the fans (see Replacing a hot-swap fan assembly).
  5. Align the compute book with the slot on the server and slide it in the server. Place one hand under the center of the compute book to support it while sliding it into the server.

    Illustration of replacing the compute book
  6. Rotate the cam handle all the way up and push it into the server until it locks in place.
  7. Reconnect the power cord and any cables that you removed.
  8. Turn on the peripheral devices and the server.