FQXSPPU0001N : An Over-Temperature Condition has been detected on [ProcessorElementName].
An Over-Temperature Condition has been detected on [ProcessorElementName].
This message is for the use case when an implementation has detected an Over-Temperature Condition Detected for Processor.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
Check the event log of XClarity Controller (XCC) for any fan- or cooling-related issues.
Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place,clean, and correctly installed.
Make sure that the room temperature is within operating specifications.
Make sure that the CPU heat sink is securely installed.
Make sure that the CPU heat sink is installed correctly and the thermal interface is correctly applied.
(Trained technician only) Replace the system board.