Skip to main content

FQXSPMA0010J : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.

[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.

This message is for the use case when an implementation has detected Memory has been Throttled.

Severity

Warning

Alert Category

System - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0142

SNMP Trap ID

22

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check the XCC event log for any fan or cooling related issues and address them first.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are correctly installed in place and keep clean.
  3. Make sure that the room temperature meets operating specifications.
  4. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
    Note
    If the device is part of a cluster solution, verify that the latest level of code is supported by the cluster solution before the update.
  5. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.