FQXSPUN0020N : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- If the sensor is in "ME Status":
- Reboot XCC and see if the issue is still observed.
- Upgrade or downgrade the UEFI to have ME update and see if the issue disappears.
- If the problem persists, contact Lenovo Support and replace the system board.
- If the sensor is in "RAID Vol State":
- Check Lenovo Support (http://support.lenovo.com/) for service bulletins, Tech tips, and firmware update related to your drive.
- Check for any other RAID-related error.
- Replace the drive and recreate an array.
- If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
Give documentation feedback