FQXSPPW0035M : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Action
Complete the following steps until the problem is solved:
- If the sensor is "CMOS Battery":
- Reboot the XCC.
- Reseat the CMOS battery.
- If the problem persists, replace the CMOS battery.
- If the sensor is "SysBrd 3.3V/5V/12V":
- Do virtual AC cycle through the XCC/BMC.
- If problem persists, collect service data log.
- AC cycle the system.
- If the problem still persists, collect service data log and contact Lenovo Support.
Give documentation feedback