6 x 2.5'' SAS/SATA + 4 x 2.5'' AnyBay backplane (two processors)
Use this section to understand the AnyBay backplane cable routing for server model with ten 2.5-inch front drives and two processors.
Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i SFF RAID adapter (Gen 3/Gen 4)
Figure 1. Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i SFF RAID adapter (Gen 3/Gen 4)


| From | To | Cable length |
|---|---|---|
| 1 SAS 0 and SAS 1 connectors on backplane | 1
|
|
| 2 Power connector on backplane | 2 Power connector 2A connector on processor board | 480 mm |
| 3 NVMe 6-7 connector on backplane | 3 PCIe connector 4 on processor board | 250 mm |
| 4 SAS 2 connector on backplane | 4
| 900 mm |
| 5 NVMe 8-9 connector on backplane | 5 PCIe connector 3 on processor board | 350 mm |
Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i CFF RAID adapter (Gen 4)
Figure 2. Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i CFF RAID adapter (Gen 4)


| From | To | Cable length |
|---|---|---|
| 1 SAS 0 connector on backplane | 1 C0 connector on RAID adapter | 175 mm |
| 2 Input connector on RAID adapter | 2 PCIe connector 8 on processor board | 450 mm |
| 3 Power connector on backplane | 3 Power connector 2A on processor board | 480 mm |
| 4 SAS 1 connector on backplane | 4 C1 connector on RAID adapter | 150 mm |
| 5 NVME 6-7 connector on backplane | 5 PCIe connector 4 on processor board | 250 mm |
| 6 NVME 8-9 connector on backplane | 6 PCIe connector 3 on processor board | 350 mm |
| 7 SAS2 connector on backplane | 7 C2 connector on RAID adapter | 210 mm |
| 8 Power connector on RAID adapter | 8 Internal RAID power connector on processor board | 210 mm |