Power off the server and disconnect all power cords for this task.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.
Procedure
Touch the static-protective package that contains the integrated diagnostics panel assembly to any unpainted surface on the outside of the server. And then, take the assembly out of the package and place it on a static-protective surface.
If there is a filler installed on the front chassis, remove it as shown.
Figure 1. Filler removal
Insert the integrated diagnostics panel into its assembly. Ensure that the panel is fully seated into its assembly.
Figure 2. Integrated diagnostics panel installation into its assembly
Slide the integrated diagnostics panel assembly into the front chassis as shown. And ensure that it is seated in place.