Skip to main content

10 x 2.5'' SAS/SATA backplane

Use this section to understand the cable routing of 10 SAS/SATA front drives for liquid cooling configuration with 10 x 2.5 AnyBay front backplane installed.

To connect power cables for a backplane for standard 2.5'' or 3.5'' drives, refer to Backplane power cable routing.

To connector cables of RAID flash power modules, refer to RAID flash power modules.

To connect signal cables, refer to the following cable routing scenarios:

Cable routing for onboard configuration

The following illustrations and tables show the mapping relationship between backplane connectors and system board (system board assembly) connectors for onboard configuration.

Figure 1. Cable routing for onboard configuration of 10 x 2.5'' SAS/SATA front drives

Table 1. Mapping between one front AnyBay backplane and system board for onboard configuration
BackplaneFromTo
Front BP (SAS)1 SAS 0, SAS 11 PCIe connector 7
2 SAS 22 PCIe connector 9

Cable routing with an SFF HBA/RAID adapter

The following tables show the mapping relationship between backplane connectors and a 16i SFF HBA/RAID adapter (Gen 3 or Gen 4).

Figure 2. Cable routing for 10 front SAS/SATA drives bays with a 16i SFF RAID adapter (Gen 3 or Gen 4)

Table 2. Mapping between one front AnyBay backplane and an SFF HBA/RAID adapter
BackplaneFromTo
Front BP (SAS)1 SAS 0, SAS 11
  • Gen 3: C0, C1

  • Gen 4: C0

2 SAS 22
  • Gen 3: C2

  • Gen 4: C1