Skip to main content

8 x 2.5'' SAS/SATA backplane

Use this section to understand the SAS/SATA backplane cable routing for server model with eight 2.5'' front drives.

To connect power cables for a backplane for standard 2.5'' or 3.5'' drives, refer to Backplane power cable routing.

To connect cables for M.2 drive backplane, refer to M.2 drive backplane.

To connector cables of RAID flash power modules, refer to RAID flash power modules.

To connect intrusion switch cable, refer to Intrusion switch.

To connect power cable for CFF RAID adapter, refer to CFF RAID adapter.

To connect signal cables for a backplane for standard 8 x 2.5'' front drives, refer to the following cable routing scenarios depending on your server configuration:

Cable routing for onboard configuration

The following illustrations and tables show the mapping relationship between backplane connectors and system board connectors for onboard configuration.

Figure 1. Cable routing for onboard configuration of 8 x 2.5 SAS/SATA front drives

Table 1. Cable routing for onboard configuration of 8 x 2.5 SAS/SATA front drives
BackplaneFromTo
Front BP (SAS)1 SAS 0, SAS 11 PCIe connector 7

Cable routing with an SFF HBA/RAID adapter

The following illustrations and tables show the mapping relationship between backplane connectors and an 8i or 16i SFF HBA/RAID adapter (Gen 3 or Gen 4).

Figure 2. Cable routing for 8 x 2.5'' front SAS/SATA drive bays with an 8i or 16i SFF RAID adapter (Gen 3 or Gen 4)

Table 2. Mapping between one front SAS/SATA backplane and an SFF HBA/RAID adapter
BackplaneFromTo
Front BP (SAS)1 SAS 0, SAS 11
  • Gen 3: C0, C1

  • Gen 4: C0

Cable routing with a CFF RAID adapter

The following illustration and table show the mapping relationship between backplane connectors and an 8i or 16i CFF RAID adapter (Gen 3 or Gen 4).
Note
The following illustration is for Gen 4 adapters. For Gen 3 adapters, the illustration might be slightly different.
Figure 3. Cable routing for 8 x 2.5'' front SAS/SATA drive bays with an 8i or 16i CFF RAID adapter (Gen 3 or Gen 4)

Table 3. Mapping between one front SAS/SATA backplane and a CFF RAID adapter
Backplane/adapterFromTo
Front BP (SAS)1 SAS 01 C0
2 SAS 12 C1
CFF RAID adapter3 MB input3 PCIe connector 7