Replacing the hard disk drive cage
This procedure applies only to 4U server models with non-hot-swap power supplies.
To install the hard disk drive cage on 4U server models with non-hot-swap power supplies, complete the following steps.
- Read the safety information in Safety and Installation guidelines.
- Turn off the server and all attached devices; then, disconnect all power cords and external cables.
- Remove the bezel (see Removing the bezel).
- Carefully turn the server on its side so that it is lying flat, with the cover facing up.AttentionDo not allow the server to fall over.
- Remove the side cover (see Removing the side cover).
- Remove the air duct.
- Press the hard disk drive cage in until the release latches click into place.NoteMake sure the backplate is already installed on the disk drive cage (see
Replacing the simple-swap backplate). - Install the air duct.
- Install the side cover (see Replacing the side cover).
- Stand the server back up in its vertical position.
- Install the bezel (see Replacing the bezel).
- Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.
Give documentation feedback