8007021b-0302ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2 QPILinkErr)
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2 QPILinkErr)
This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
May also be shown as 8007021b0302ffff or 0x8007021b0302ffff
Internal Event
No
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Response
- Check for a server firmware update.
- Make sure that the installed microprocessors are compatible.
- (Trained technician only) Replace the microprocessor if the problems still exist
- (Trained technician only) Replace the system board if the problems still exist.
Give documentation feedback