806f000f-22010bff : Firmware BIOS (ROM) corruption was detected on system [ComputerSystemElementName] during POST. (ABR Status)
Firmware BIOS (ROM) corruption was detected on system [ComputerSystemElementName] during POST. (ABR Status)
Firmware BIOS (ROM) corruption was detected on the system during POST.
May also be shown as 806f000f22010bff or 0x806f000f22010bff
Internal Event
No
Severity
Info
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
40
Automatically Notify Support
No
User Response
- Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
- Recover the server firmware from the backup page: a.Restart the server. b.At the prompt, press F3 to recover the firmware.
- Update the server firmware to the latest level (see Updating the firmware). Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
- Remove components one at a time, restarting the server each time, to see if the problem goes away.
- If the problem remains, (trained service technician) replace the system board.
Give documentation feedback