806f020d-0404ffff : Failure Predicted on drive [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 4)
Failure Predicted on drive [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 4)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0404ffff or 0x806f020d0404ffff
Internal Event
No
Severity
Warning
Alert Category
System - Predicted Failure
Serviceable
Yes
SNMP Trap ID
27
Automatically Notify Support
Yes
User Response
- Run the hard disk drive diagnostic test on drive n.
- Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
- Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
Give documentation feedback