Remove the integrated diagnostics panel assembly

Use this information to remove the integrated diagnostics panel assembly.

About this task

Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.

  • Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.

  • Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding systems.

Procedure

  1. Remove the top cover. See Remove the top cover.
  2. If the security bezel is installed, remove it. See Remove the security bezel.
  3. Remove the integrated diagnostics panel assembly from the chassis.
    Figure 1. Integrated diagnostics panel assembly removal
    Integrated diagnostics panel assembly removal

    1. Press down the extended tab on the other side of the front chassis.
    2. Slide the assembly out of the front chassis.
  4. Remove the integrated diagnostics panel from its assembly.
    Figure 2. Integrated diagnostics panel removal
    Integrated diagnostics panel removal

    1. Press down the clips as shown.
    2. Pull the integrated diagnostics panel by its handle to get it out of its assembly.

After you finish

  1. Install a new integrated diagnostics panel assembly or filler. See Install the integrated diagnostics panel assembly.

  2. If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.

Demo video

Watch the procedure on YouTube