Use this information to install the serial port module.
Before installing the serial port module, touch the static-protective package that contains the new serial port module to any unpainted surface out of the server. Then, take the new serial port module out of the package and place it on a static-protective surface.
To install the serial port module, complete the following steps:
The serial port module can be installed on riser 1 assembly or riser 2 assembly. The following steps are based on the scenario that the serial port module is to be installed on riser 2 assembly. The installation procedure is the same for the serial port module to be installed on riser 1 assembly.
- Grasp the riser assembly by its edges and carefully lift it out of the server.
Figure 1. Riser assembly removal - If the riser assembly is covered with a PCIe slot bracket, remove the bracket first. Then, install the serial port module into the riser assembly.
Figure 2. Serial port module installation - Insert the riser assembly into the riser slot on the system board. Ensure that the riser assembly is fully seated.
- Connect the cable of the serial port module to the serial-port-module connector on the system board. For the location of the serial-port-module connector, refer to System board components. If the serial port module is installed in PCIe slot 1, route the cable of the serial port module as shown.
Figure 3. Cable routing for serial port module installed in PCIe slot 1
After installing the serial port module, do one of the following to enable it according to the installed operating system:
For Linux operating system:
Open the ipmitool and enter the following command to disable the Serial over LAN (SOL) feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
For Microsoft Windows operating system:
Open the ipmitool and enter the following command to disable the SOL feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
Open Windows PowerShell and enter the following command to disable the Emergency Management Services (EMS) feature:
Bcdedit /ems no
Restart the server to ensure that the EMS setting takes effect.