Technical rules for drives
The following notes describe the types of drives that your server support and other information that you must consider when you install a drive.
- Depending on your server models, your server supports the following types of drives:
SAS/SATA HDD
SAS/SATA SSD
NVMe SSD
For a list of supported drives, see: Lenovo ServerProven website
NoteVMware ESXi does not support ThinkSystem 2.5 U.3 6500 ION 30.72TB Read Intensive NVMe PCIe 4.0 x4 HS SSD.
The drive bays are numbered to indicate the installation order (starting from number “0”). Follow the installation order when you install a drive. See Front view.
- You can mix drives of different types and different capacities in one system, but not in one RAID array. The following priorities are recommended:
Drive type priority: NVMe SSD, SAS SSD, SATA SSD, SAS HDD, SATA HDD
Drive capacity priority: the lowest capacity first
The drives in a single RAID array must be the same type, same size, and same capacity.
If you select 12 or 14 TB 3.5-inch SAS/SATA drives, only standard fan is supported.
- For middle drive cage:
- Only NVMe drives are supported.NoteOnly 7 mm NVMe drives are supported based on thermal consideration.
High-performance fan should be selected, and the supported ambient temperature is up to 30°C.
- For rear drive cage:
- Both SAS/SATA and NVMe drives are supported.NoteFor NVMe drives, only 7 mm NVMe drives are supported based on thermal consideration.
High-performance fan should be selected, and the supported ambient temperature is up to 30°C.
Supported processor TDP is 120/155 watts.
For 6 SAS/SATA +4 anybay backplane configuration
Note2.5 or U.2 Gen4 NVMe drives (except Gen3 NVMe drives) are not supported.