Remove the front I/O module

Follow instructions in this section to remove the front I/O module.

About this task

Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.

  • Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.

  • Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.

Procedure

  1. Make preparation for the task.
    1. If the security bezel is installed, remove it. See Remove the security bezel.
    2. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover, or remove the server from the rack. See Remove the server from rack.
    3. Remove the top cover. See Remove the top cover.
    4. Remove the air baffle. See Remove the air baffle.
  2. Disconnect the cables of the front I/O module from the system board assembly.
    Attention
    To avoid damaging the system board assembly, make sure to follow the instructions in Internal cable routing when disconnecting cables from the system board assembly.
  3. Remove the front I/O module from the front chassis.
    Figure 1. Front I/O module with the front operator panel
    Front I/O module with the front operator panel
    Figure 2. Front I/O module with the integrated diagnostics panel
    Front I/O module with the integrated diagnostics panel
    1. Remove the screw that secure the front I/O module.
    2. Slide the front I/O module out of the front chassis.
  4. (Optional) If you are replacing the integrated diagnostics panel, remove the diagnostics panel from the front I/O module.
    Figure 3. Removing the integrated diagnostics panel
    Removing the integrated diagnostics panel
    1. Press down the clips as shown.
    2. Pull the diagnostics panel by its handle to get it out of its assembly.

After you finish

If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.