Skip to main content

Install a fan module

Follow the instructions in this section to install a hot-swap fan.

About this task

S014
shock hazard
CAUTION
Hazardous voltage, current, and energy levels might be present. Only a qualified service technician is authorized to remove the covers where the label is attached.
S017
moving parts
CAUTION
Hazardous moving fan blades nearby. Keep fingers and other body parts away.
S033
240VA shock hazard
CAUTION

Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with metal, which might result in spattered metal, burns, or both.

Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.

  • Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.

  • Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.

  • If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top covers, or remove the server from the rack. See Remove the server from rails.

Procedure

Align the fan module over the fan slot in the fan cage assembly, and insert the fan module into the fan cage assembly until it clicks into place.
Figure 1. Installing a fan module
Installing a fan module
Note
  • Make sure to replace a defective fan module with another unit of the exact same type.

  • Do not mix single and dual rotor fan modules in the same unit of server.

Attention
With power on, complete the replacement within 30 seconds to ensure proper operation.

After you finish

  1. Reinstall the front top cover. See Install the front top cover.

  2. Complete the parts replacement. See Complete the parts replacement.

Demo video

Watch the procedure on YouTube