Removing and replacing Tier 1 CRUs
Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request, you will be charged for the installation.
The illustrations in this document might differ slightly from your hardware.
- Removing and installing drives
 Use this information to remove and install drives.
- Removing an adapter
 Use this information to remove an adapter.
- Installing an adapter
 Use this information to install an adapter.
- Removing the SD adapter
 Use this information to remove the SD adapter.
- Replacing the SD adapter
 Use this information to replace a SD adapter.
- Removing a remotely installed RAID adapter battery or flash power module
 Use this information to remove a RAID adapter battery or flash power module remotely in the server.
- Installing a RAID adapter battery or flash power module remotely in the server
 Use this information to install a RAID adapter battery or flash power module remotely in the server.
- Removing an optional ServeRAID adapter memory module
 Use this information to remove an optional ServeRAID adapter memory module.
- Installing an optional ServeRAID adapter memory module
 Use this information to install an optional ServeRAID adapter memory module.
- Removing a hot-swap fan
 Use this information to remove a hot-swap fan in the server.
- Installing a hot-swap fan
 Use this information to install a hot-swap fan in the server.
- Removing the system battery
 Use this information to remove the system battery.
- Installing the system battery
 Use this information to install the system battery.
- Removing the light path diagnostics assembly
 Use the information to remove the light path diagnostics assembly.
- Installing the light path diagnostics assembly
 Use the information to install the light path diagnostics assembly.
- Removing the USB assembly
 Use the information to remove the USB assembly.
- Installing the USB cable assembly
 Use the information to install the USB cable assembly.
- Removing the 2.5-inch hard disk drive backplane
 Use this information to remove the 2.5-inch hard disk drive backplane.
- Installing the 2.5-inch hard disk drive backplane
 Use this information to install the 2.5-inch hard disk drive backplane.
- Removing the 3.5-inch hard disk drive backplane
 Use this information to remove the 3.5-inch hard disk drive backplane.
- Installing the 3.5-inch hard disk drive backplane
 Use this information to install the 3.5-inch hard disk drive backplane.
- Removing a hot-swap power supply
 Use this information to remove a hot-swap power supply.
- Installing a hot-swap power supply
 Use this information to install a hot-swap power supply.
- Removing the operator information panel assembly
 Use this information to remove the operator information panel assembly.
- Installing the operator information panel assembly
 Use this information to install the operator information panel assembly.
- Removing a memory module
 Use this information to remove a memory module.
- Memory module installation
 The following notes describe the types of DIMMs that the server supports and other information that you must consider when you install DIMMs.
- Removing a USB embedded hypervisor flash device
 Use this information to remove a USB embedded hypervisor flash device.
- Installing a USB embedded hypervisor flash device
 Use this information to install a USB embedded hypervisor flash device.
- Removing the fan cage assembly
 Use this information to remove the fan cage assembly from the server.
- Installing the fan cage assembly
 Use this information to install the fan cage assembly from the server.
- Removing the left-side cover/power cut-off switch assembly
 Use this information to remove the left-side cover/power cut-off switch assembly.
- Installing the left-side cover/power cut-off switch assembly
 Use this information to install the left-side cover/power cut-off switch assembly.
Give documentation feedback