Removing and replacing Tier 1 CRUs
Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request, you will be charged for the installation.
The illustrations in this document might differ slightly from your hardware.
- Removing and installing drives
Use this information to remove and install drives. - Removing an adapter
Use this information to remove an adapter. - Installing an adapter
Use this information to install an adapter. - Removing the SD adapter
Use this information to remove the SD adapter. - Replacing the SD adapter
Use this information to replace a SD adapter. - Removing a remotely installed RAID adapter battery or flash power module
Use this information to remove a RAID adapter battery or flash power module remotely in the server. - Installing a RAID adapter battery or flash power module remotely in the server
Use this information to install a RAID adapter battery or flash power module remotely in the server. - Removing an optional ServeRAID adapter memory module
Use this information to remove an optional ServeRAID adapter memory module. - Installing an optional ServeRAID adapter memory module
Use this information to install an optional ServeRAID adapter memory module. - Removing a hot-swap fan
Use this information to remove a hot-swap fan in the server. - Installing a hot-swap fan
Use this information to install a hot-swap fan in the server. - Removing the system battery
Use this information to remove the system battery. - Installing the system battery
Use this information to install the system battery. - Removing the light path diagnostics assembly
Use the information to remove the light path diagnostics assembly. - Installing the light path diagnostics assembly
Use the information to install the light path diagnostics assembly. - Removing the USB assembly
Use the information to remove the USB assembly. - Installing the USB cable assembly
Use the information to install the USB cable assembly. - Removing the 2.5-inch hard disk drive backplane
Use this information to remove the 2.5-inch hard disk drive backplane. - Installing the 2.5-inch hard disk drive backplane
Use this information to install the 2.5-inch hard disk drive backplane. - Removing the 3.5-inch hard disk drive backplane
Use this information to remove the 3.5-inch hard disk drive backplane. - Installing the 3.5-inch hard disk drive backplane
Use this information to install the 3.5-inch hard disk drive backplane. - Removing a hot-swap power supply
Use this information to remove a hot-swap power supply. - Installing a hot-swap power supply
Use this information to install a hot-swap power supply. - Removing the operator information panel assembly
Use this information to remove the operator information panel assembly. - Installing the operator information panel assembly
Use this information to install the operator information panel assembly. - Removing a memory module
Use this information to remove a memory module. - Memory module installation
The following notes describe the types of DIMMs that the server supports and other information that you must consider when you install DIMMs. - Removing a USB embedded hypervisor flash device
Use this information to remove a USB embedded hypervisor flash device. - Installing a USB embedded hypervisor flash device
Use this information to install a USB embedded hypervisor flash device. - Removing the fan cage assembly
Use this information to remove the fan cage assembly from the server. - Installing the fan cage assembly
Use this information to install the fan cage assembly from the server. - Removing the left-side cover/power cut-off switch assembly
Use this information to remove the left-side cover/power cut-off switch assembly. - Installing the left-side cover/power cut-off switch assembly
Use this information to install the left-side cover/power cut-off switch assembly.
Give documentation feedback