FQXST0058W : A disk drive reset itself due to an internal logic error.
A disk drive reset itself due to an internal logic error.
Severity
Critical
Serviceable with log
No
Automatically Notify Support
No
User Action
- The first time this event is logged with a severity of Warning, update the disk firmware if the specified disk is not running the latest firmware.
- If this event is logged with severity of Warning for the same disk more than five times in one week, and the specified disk is running the latest firmware, replace the disk with one of the same type (SAS SSD, enterprise SAS, or midline SAS) and the same or greater capacity. For continued optimum I/O performance, the replacement disk should have performance that is the same as or better than the one it is replacing.
Give documentation feedback