FQXST0554W : A voltage sensor is not within the normal operating range but is within safe operating limits; or, a voltage sensor was removed.
A voltage sensor is not within the normal operating range but is within safe operating limits; or, a voltage sensor was removed.
Severity
Critical
Serviceable with log
No
Automatically Notify Support
No
User Action
If a voltage sensor has exceeded the normal operating range but is within safe operating limits:
- Check that all modules in the enclosure are fully seated in their slots and that their latches are locked.
- If this does not resolve the issue, the specified FRU has probably failed and should be replaced.
If a voltage sensor has been removed:
- Check that the specified FRU is in the specified enclosure.
- If the FRU is not in the enclosure, install the FRU immediately.
- If the FRU is in the enclosure, ensure that the FRU is fully seated in its slot and that its latches are locked.
- If this does not resolve the issue, the specified FRU has probably failed and should be replaced.
When the problem is resolved, an event with the same code will be logged with a severity of Resolved.