FQXST0486W : A recovery process was initiated to prevent writing outdated data that might exist in the controller that logged this event.
A recovery process was initiated to prevent writing outdated data that might exist in the controller that logged this event.
Severity
Critical
Serviceable with log
No
Automatically Notify Support
No
User Action
- Wait at least five minutes for the automatic recovery process to complete. Then sign in and confirm that both controller modules are operational. (You can determine if the controllers are operational with the show redundancy-mode CLI command.) In most cases, the system will come back up and no action is required.
- If both controller modules do not become operational in five minutes, see the recommended actions for event 485, which will be logged at approximately the same time.