FQXST0552W : An EMP reported one of the following:
An EMP reported one of the following:
Severity
Critical
Serviceable with log
No
Automatically Notify Support
No
User Action
If a fan in the specified FRU has been uninstalled:
- Check that the specified FRU is in the specified enclosure.
- If the FRU is not in the enclosure, install the appropriate FRU immediately.
- If the FRU is in the enclosure, ensure that the FRU is fully seated in its slot and that its latch is locked.
- If none of the above resolves the issue, the specified FRU has failed and should be replaced.
If a fan in the specified FRU has failed and fan redundancy for the FRU has been lost:
- The specified FRU has failed and should be replaced.
When the problem is resolved, an event with the same code will be logged with a severity of Resolved.