FQXSPCA0015J : Sensor [SensorElementName] has transitioned from normal to non-critical state.
Sensor [SensorElementName] has transitioned from normal to non-critical state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.
Severity
Warning
Alert Category
Warning - Temperature
Serviceable
Yes
SNMP Trap ID
12
Automatically Notify Support
No
User Action
Complete the following steps:
- Check the event log of System Management Module 2 (SMM2) and XClarity Controller for any fan- or cooling-related issues or power-related issues.
- Make sure that the airflow is not obstructed and that fillers are in place, clean and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Reseat the M.2 adapter if the problem still exists.
Give documentation feedback