FQXSPMA0005N : Subsystem [MemoryElementName] has insufficient memory for operation.

Subsystem [MemoryElementName] has insufficient memory for operation.

This message is for the use case when an implementation has detected that the usable Memory is insufficient for operation.

Severity​

Error

Alert Category​

Critical - Memory

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0132

SNMP Trap ID​

41

Automatically Notify Support​

No

User Action​

Complete the following steps:

  1. Ensure one or more DIMMs have been installed in the compute node.
  2. Resolve existing memory errors if they are present.
  3. If no memory fault is recorded in the logs, verify that all DIMM connectors are enabled using the Setup utility or the OneCLI utility.
  4. Reseat all DIMMs ensuring that DIMMs are installed in the correct population sequence, according to the service information for this product.
  5. Clear the CMOS memory on the system board. Note that all firmware settings will revert to the defaults.
  6. Reflash UEFI firmware.
  7. If the problem persists, collect the Service Data log.
  8. Contact Lenovo Support.