FQXSPPW0047M : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Action
Complete the following steps:
- Reseat the identified compute node.
- If the specified sensor is system board 12V, ensure PDB is installed correcly and check the XClarity Controller event log for power-supply-related issues, and resolve those issues.
- If the specified sensor is system board 3.3V or system board 5V, (trained technician only) replace the defective node tray.
- If the problem persists, (trained technician only) replace the PDB or the defective node tray.